| Standard Optional |
| User Interface |
Emergency stop switch
Alarm horn
Annunciator lamps
Generator set master switch, run/off-reset/auto positions
Digital display
Keypad
Operating guide
Controller terminal strips |
| ------------------------------------------------------------------------ |
| Measurement |
Battery voltage
Coolant-level
Coolant-pressure
Coolant-temperature
Engine start countdown
Fuel-pressure
Fuel-temperature
Fuel- rate expressed as L/hr. (gal./hr.)
Fuel-used last run expressed as L (gal.)
As the accumulated fuel quantity
Oil- level and crankcase pressure
Oil- pressure
Oil- temperature
Rpm
Temperature-ambient
Generator monitoring data:
Current (L1,L2,L3 +-0.25% accuracy
Frequency+-0.5% accuracy
Kilowatts, total per phase (L1, L2, L3),+-0.5% accuracy
KVA, total per phase (L1, L2, L3),+-0.5% accuracy
KVAR, total absorbing/generating per phase (L1, L2, L3),+-0.5% accuracy
Percent alternator duty level (actual load kW/rating)
Power factor per phase, leading/lagging
Voltage (line to line, line-to neutral for all phases), +_0.25% accuracy |
| ------------------------------------------------------------------------ |
| Indicator Light/Messages |
Alarm horn
Five LED status indicating lights
Indicators:
Not in auto (yellow)
Program mode (yellow)
System ready (green)
System shutdown (red)
System warning (yellow)
Switches and standard features:
Keypad, 16 button multifunction sealed membrane
Lamp test
Switch, auto, off/reset, run (engine start)
Latch-type emergency stop switch with International
Electromechanical Commission (IEC) yellow ring identification |
| |
|
|
| Standard Optional |
| Automatic Functions |
Alternator protection
Idle speed start
Voltage regulation
Cool-down mode
Battle switch mode
Load shed mode
Paralleling relays for KOHLER PD Series switchgear |
| -------------------------------------------------- |
| Operational Records |
Event history (stores up to 100 system events)
Last start of starts
Number of starts
Number of starts since last maintenance
Operating days since last maintenance
Operating mode-standby or prime power
Run time since maintenance (total, loaded, and unloaded hours and total kW hours)
System shutdowns
System shutdowns
Time, date and day of week |
| -------------------------------------------------- |
| Accessories |
Monitor III Software of monitoring and control (Windows based user interface)
Converter, Modbus/ Ethernet Run realy
Key –controlled, master switch
Prime power switch
Remote enunciator panel |
| -------------------------------------------------- |
|